Mô tả

1. Characteristics of this device

This device is shrink fit device to be heated by electromagnetic induction.

  • Holder Material: Steel・Sus Line
  • Automatically arrange voltage from AC 100V ~240V
  • Tool Material : Carbide
  • Light and easy to install in small area (325 x 340 x 690H),Weight:25Kg
  • Able to do shrink fit in short time
  • Able to do shrink fit for tools with Φ 3~3.2 shank diameter
  • Easy to operate
  • Reasonable price is achieved

2. Location to be installed

  • Please install this device at flat area
  • Please use the outlet corresponding to single phase AC100V~240V
  • Please use rated capacity power.
  • Please avoid the place with dust and vibration when installing. It may be cause of troubles.

3. Specification

  • Name: ELECTROMAGNETIC INDUCTION SHRINK FIT DEVICE
  • Type: SF3300
  • Heating method: Electromagnetic induction heating method
  • Heating capacity: 3mm~32mm
  • Power: Single phase AC 100V~240 V 50.60Hz
  • Maximum consumption power: 3.6kw when operating in 220V
  • Weight: 25kg
  • Size: 380mm (horizontal) x 350mm (vertical) x 720mm (height)

4. Standard parts

  • Heating coil: HC-30 (inside diameter Φ 30 mm) 1 ea
  • Tool base: heat-resistance gloves 1
  • Fuse

5. Option

   1.Heating coil

        φD   L

  • HC-20:20 50
  • HC-30:30    50
  • HC-40:40    50
  • HC-50:50  50

 2. Stopper arranging tools

  •   For BT30, HSK32, 40
  •   For BT40, HSK50, 63
  •   For BT50, HSK100

6. How to set up air device

   1) How to set up cooling time

  • Press approx. 8 seconds [SET-TIME] key on panel
  • [A1] appears and changes to air time mode
  • Input figure with key board and set up cooling time
  • Each unit: setting up 30 seconds
  • 60 seconds: [02]=> [AIR TIME]
  • 120 seconds: [04] => [AIR TIME]
  • Once cooling time is set up, it will be memorized even after power is off.

7. Name of parts

(1) Power outlet

  • 1) Corresponding to 100V~240V
  • 2) Please put to earth to prevent damage or short circuit

(2) Fuse

Change of fuse

  • 1) Put plug out a socket (Please plug out to prevent electric shock)

(3) Connector for cooling device(air)

  • 1) Voltage controlling DC 24V 50Ma
  • 2) Please use proper clamp
  • 3) Please use proper device for the output

(4) Connector for heating coil

  • 1) Please turn it off when connecting
  • 2) Please connect only with our heating coil

8. How to Operate

(1) Input figure with key board and set up heatingtime

For example

  • 10 seconds: [10]=> [HEATNG TIME]
  • 5 seconds: [05] => [HEATING TIME]

(2) Emergency stop

  • Please press emergency stop SW for sudden stop and heating stops.
  • Turn the emergency stop
  • button to the right after checking if there are problems for releasing emergency stop function.

 (3) Alarm

Details of alarm is shown on data display

E O O : abnormal output transistor

When the temperature of output transistor goes over 50℃ by surrounding temperature environment and more than 10 minute heating, E O O appears on stop timer display (over heating prevention sensor)

[How to cancel] When the temperature reaches 50~60℃ with rear fan ON, E 0 0 disappears and automatically returns to normal condition (able to use after 10~20 minutes)

E 0 2: over current

[How to cancel] Circuit is in sleep mode. Heating restarts when pressing restart button.

The alarm reappears when the size of holder and coil is not matched. Please use bigger heating coil.

9. Heating time table

10. Quality guarantee: 1 years

  • Free repair service: any troubles occurs during normal use for the quality guarantee period
  • Paid repair service: The product out of guaranty
  • Any troubles caused by not following manual
  • Damage or troubles caused by external shock or dropping the products Troubles caused by Acts of God

Đánh giá

Chưa có đánh giá nào.

Hãy là người đầu tiên nhận xét “MÁY GIA NHIỆT SF3300 – Machine For Shrink Fit Extension Chuck”

Email của bạn sẽ không được hiển thị công khai. Các trường bắt buộc được đánh dấu *